Why the cable matters
Layer 1 problems, such as a bad cable or the wrong cable type, cause a large share of real network faults. Knowing what each cable can do, and how far, saves hours of guessing.
UTP copper cable
UTP means Unshielded Twisted Pair: 8 copper wires twisted into 4 pairs inside one jacket. The twisting cancels electrical noise from nearby cables and motors. The plug at each end is an RJ45 connector, and the socket on the wall or switch is an RJ45 port. Cables are sold by category (Cat). Higher categories are built to handle higher frequencies, so they carry faster speeds.
| Category | Typical use | Notes |
|---|---|---|
| Cat5e | 1 Gbps up to 100 m | Still common, fine for most desks |
| Cat6 | 1 Gbps up to 100 m; 10 Gbps only for short runs (about 55 m) | Thicker, better noise protection |
| Cat6a | 10 Gbps up to 100 m | The usual choice for new office cabling and Wi-Fi 6/7 access points |
The maximum length of one copper Ethernet run is 100 metres, from the switch to the device, including patch cords. Longer runs need a switch in between or fibre.
Straight-through, crossover and Auto-MDIX
Copper Ethernet sends on some wires and receives on others. A PC, router or server sends on one pair; a switch or hub expects to receive on that pair. So a PC-to-switch link uses a straight-through cable (same wire order at both ends). Two devices of the same kind, such as switch to switch, PC to PC, or router directly to PC, need a crossover cable, where the send and receive pairs are swapped.
| Connection | Cable without Auto-MDIX |
|---|---|
| PC to switch, router to switch | Straight-through |
| Switch to switch, PC to PC | Crossover |
| Router to PC (direct) | Crossover |
Most modern switches and NICs support Auto-MDIX: the port detects the cable type and swaps the pairs itself, so either cable works. Almost all gigabit ports handle it. You still need to know the rule for exams and for old equipment.
Fibre optic cable
Fibre carries pulses of light through a thin glass core. It is immune to electrical interference, cannot be tapped easily, and reaches much further than copper. It is used between buildings, between floors (backbone links), in data centres, and by ISPs for FTTH.
- Multimode fibre (MMF): a wider core, cheaper optics, used for distances of a few hundred metres, inside buildings and data centres. Usually an orange or aqua jacket.
- Single-mode fibre (SMF): a very thin core (about 9 micrometres) and laser light, reaching many kilometres. Used between campus buildings and by ISPs. Usually a yellow jacket.
Reading Ethernet standard names
A name like 1000BASE-T has three parts: the speed in Mbps (1000), BASE for baseband signalling, and the medium (T for twisted pair copper; S and L for short and long wavelength fibre).
| Standard | Speed | Medium | Typical reach |
|---|---|---|---|
| 100BASE-TX | 100 Mbps | Cat5 or better copper | 100 m |
| 1000BASE-T | 1 Gbps | Cat5e or better copper | 100 m |
| 10GBASE-T | 10 Gbps | Cat6a copper | 100 m |
| 1000BASE-SX | 1 Gbps | Multimode fibre | Up to about 550 m |
| 1000BASE-LX | 1 Gbps | Single-mode fibre (also multimode, shorter) | About 5 to 10 km on single-mode |
| 10GBASE-SR | 10 Gbps | Multimode fibre | About 300 m (OM3) to 400 m (OM4) |
| 10GBASE-LR | 10 Gbps | Single-mode fibre | 10 km |
SFP modules
Many switches have empty slots called SFP ports. You plug in a small transceiver module (SFP for 1 Gbps, SFP+ for 10 Gbps) that matches the fibre type and distance you need, such as an SX module for multimode. This lets one switch model serve many cabling situations.
Power over Ethernet (PoE)
PoE lets a switch send power down the same UTP cable as data, so IP phones, access points and CCTV cameras need no separate power socket. The standards, with the power a switch port can supply:
- 802.3af (PoE): up to 15.4 W per port. Enough for IP phones and simple cameras.
- 802.3at (PoE+): up to 30 W. Common for access points and PTZ cameras.
- 802.3bt (PoE++): up to 60 W (Type 3) or 90 W (Type 4). For powerful APs, displays and small devices.
Some power is lost in the cable, so the device receives a little less than the port supplies. Check the switch total PoE budget too: a 24-port switch may not power all 24 ports at full power at once.
Need help?
Stuck on a word or an idea? Search this course, or every course, and jump straight to the explanation or a worked question.
Try:
Watch the lesson
Cables, fibre and Ethernet standards · 1/7
Layer one is the cable, and many real faults live here. Let us learn the media.
Prefer a video by a teacher? Find free videos on “Ethernet cables Cat5e Cat6 straight through crossover fiber single mode multimode CCNA” on YouTube ↗
In real life: Cabling a new office in Hyderabad
A startup leases two floors. Each desk gets a Cat6a run to the floor switch, all under 90 m. Ceiling access points and IP cameras get PoE+ from the same switches. The two floor switches link to the core switch in the server room over multimode fibre with 10GBASE-SR SFP+ modules. A second building across the road, 600 m away, is joined with single-mode fibre and 10GBASE-LR modules, because multimode would not reach.
Practice (0/3 done)
Without Auto-MDIX, which cable joins two switches?
Write cable_for(a, b) that returns "straight-through" or "crossover" for two devices on a port WITHOUT Auto-MDIX. Group 1 is "pc", "router", "server"; group 2 is "switch", "hub". Devices from different groups need "straight-through"; devices from the same group need "crossover".
You need to join two buildings 3 km apart at 10 Gbps. Which standard fits?
Quick quiz
Read more (free)
Related help
Before this, learn
This topic builds on these. If something here feels new, open them first.
Related topics
- Ethernet frames and MAC addressesEthernet, MAC addresses and the Cisco CLI · same module
- How a switch learns and forwardsEthernet, MAC addresses and the Cisco CLI · same module
- ARP, the default gateway and pingEthernet, MAC addresses and the Cisco CLI · same module
- Why layer 2 loops are deadlySpanning Tree and EtherChannel
- VLANs: what they are and why we use themSwitching and VLANs
- OSPF concepts: link state, areas and neighboursRouting: static routes and OSPF
Questions people ask about this
Open a question to see the answer and why. The first ones are this topic's own quiz, so try the quiz above before you peek.
What is the maximum length of a standard copper Ethernet run?
Answer: 100 m
UTP Ethernet standards such as 1000BASE-T are specified for 100 m.
Which cable category supports 10 Gbps over the full 100 m?
Answer: Cat6a
Cat6a is built for 10GBASE-T at 100 m.
Why is fibre used between buildings?
Answer: It carries light, ignores electrical interference and reaches much further
Fibre is immune to electrical noise and works over kilometres.
An access point needs about 25 W. Which is the lowest PoE standard that can supply it?
Answer: 802.3at (PoE+)
PoE+ supplies up to 30 W per port; 802.3af only up to 15.4 W.
What does the "T" in 1000BASE-T mean?
Answer: Twisted pair copper
T means twisted pair copper cable.
Which device turns the light on an FTTH fibre into Ethernet at a customer home?Related
Answer: ONT
An Optical Network Terminal (ONT) ends the fibre and gives an Ethernet port.
From Network devices
What is the largest payload a standard Ethernet frame can carry?Related
Answer: 1500 bytes
The standard Ethernet MTU is 1500 bytes. 9000 is a non-standard jumbo frame.
Every PC on each floor of an office plugs into one switch, and the floor switches connect to two core switches that are linked to each other. Which topology is this best described as?Related
Answer: Hybrid
Stars on each floor joined by a meshed core is a mix of topologies, called hybrid.
From What a network is
A switch log keeps saying a host is "flapping between port Gi0/1 and port Gi0/2". What does this suggest?Related
Answer: A layer 2 loop
MAC flapping means the same source MAC keeps arriving on different ports, a typical sign of a loop.
Pass the quiz (60% or more) or mark this topic as done when you are ready.